Micro-Aide LDM-1 Manuel d'utilisateur Page 17

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 16
Setup and Installation - Network Types
11
• The RTS signal of the master modem can be permanently asserted. Refer to
the section entitled “Permanently Asserting the RTS” on page 15.
• RTS-CTS flow control must be used by each DTE device connected to a
slave modem.
• The near- to far-end cable length must not exceed the recommendations as
listed in Table 5 on page 30 for the given cable size and selected Baud rate.
The Equalization setting for the near- and far-end modems must be identical
and set in accordance with the recommendations as listed in Table 6 on
page 31. Assume a cable length equal to the near-end to far-end cable length.
• The Equalization setting for a drop point modem must also be set in accor-
dance with the recommendations as listed in Table 6 on page 31. Assume a
cable length equal to the length between the near-end modem (i.e., master)
and the drop point modem.
Figure 4 - Typical Multi-Drop Network